{"product_id":"vsail-addressable-fire-control-panel-single-loop-100-devices-vi-6811-100","title":"VSAIL Addressable Fire Control Panel Single Loop 100 Devices VI-6811\/100","description":"\u003cdiv class=\"markdown markdown-main-panel md-content enable-luminous-fast-follows enable-updated-hr-color stronger tutor-markdown-rendering\" id=\"model-response-message-contentr_7058534ebd4e88fd\" dir=\"ltr\"\u003e\n\u003cdiv\u003e\u003cb\u003eVSAIL Addressable Fire Control Panel Single Loop 100 Devices VI-6811\/100\u003c\/b\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv\u003eThe \u003cb\u003eVSAIL VI-6811\/100 Intelligent Addressable Fire Alarm Control Panel\u003c\/b\u003e provides reliable, economic fire protection designed for small-to-medium commercial and residential facilities. Featuring a single detection loop capable of supporting up to 100 addressable field devices (such as smoke detectors, heat sensors, manual call points, and module interfaces), this compact panel allows precise point-by-point identification during fire alerts or fault events.\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv\u003e\n\u003cspan class=\"citation-27 citation-end-27\"\u003eBuilt with a user-friendly LCD screen, clear LED status indicators, and an integrated 1,000-event history log, the VI-6811\/100 simplifies daily monitoring, event diagnostics, and system testing.\u003csup class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-26 citation-end-26\"\u003eIts 8-zone logic configuration, dedicated sounder output circuit, and passive relay contacts ensure seamless integration with local alarm notification devices and central monitoring systems.\u003csup class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv\u003eAvailable at \u003cb\u003eElectx Electrical Supply\u003c\/b\u003e (\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.google.com\/search?q=https%3A%2F%2Fwww.electxelectricalsupply.com\" class=\"ng-star-inserted\" target=\"_blank\"\u003ewww.electxelectricalsupply.com\u003c\/a\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e), your trusted partner for commercial electrical products, life safety controls, and power distribution equipment in Quiapo, Manila.\u003c\/div\u003e\n\u003cbr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature \/ Property\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eBrand\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVSAIL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eModel Code\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVI-6811\/100 (also referenced as VG-6811\/100)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003ePanel Type\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntelligent Single-Loop Addressable Fire Control Panel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eLoop Capacity\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 100 Addressable Devices\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eMain Power Supply\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC 180V – 252V @ 50Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eLoop Operating Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC 15V – 28V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eLoop Current \/ Short Circuit\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200mA Normal \/ Max 400mA Short Circuit Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eSounder Circuit Output\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 Conventional Output (DC 24V \/ 300mA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003ePassive Relay Outputs\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Relay Outputs for Fire and Fault (DC 30V \/ 1A)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eZonal Mapping\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Programmable Logic Zones\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eEvent History Memory\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBuilt-in non-volatile storage up to 1,000 event logs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eCommunication \/ Network\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS232 Serial Port Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eOperating Environment\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10°C to +50°C; Humidity ≤95% RH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eEnclosure Dimensions\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 320mm × 240mm × 68mm (Wall-Mount)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eAuthorized Retailer\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eElectx Electrical Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Features \u0026amp; System Advantages\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cb\u003ePinpoint Point-Addressable Detection:\u003c\/b\u003e Identifies the precise location of smoke, heat, or manual pull station activations across all 100 connected devices.\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cb\u003eBuilt-In Notification \u0026amp; Outputs:\u003c\/b\u003e \u003cspan class=\"citation-25 citation-end-25\"\u003eFeatures a dedicated 24V conventional sounder loop alongside passive relay contacts to trigger auxiliary fire dampers, door holders, or remote reporting systems.\u003csup class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cb\u003eIntuitive Diagnostic Interface:\u003c\/b\u003e \u003cspan class=\"citation-24 citation-end-24\"\u003eIntegrated LCD screen and front-panel status LEDs give maintenance personnel immediate visibility into normal, fire, fault, and disablement states.\u003csup class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cb\u003eCompact Wall-Mount Form Factor:\u003c\/b\u003e Space-saving enclosure simplifies wall mounting inside electrical closets, security rooms, or main entrances.\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cb\u003eCost-Effective Small Project Solution:\u003c\/b\u003e Ideal for boutique hotels, office branches, restaurants, retail shops, and bank branches requiring addressable fire protection without multi-loop complexity.\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; System Setup Overview\u003c\/h3\u003e\n\u003col start=\"1\"\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cb\u003eMounting:\u003c\/b\u003e Securely mount the panel backbox to a structural wall in a dry, accessible area in accordance with local fire codes.\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cb\u003ePower Wiring:\u003c\/b\u003e \u003cspan class=\"citation-23 citation-end-23\"\u003eWire the main AC power lines (180V–252V AC) directly to the designated power module terminals and connect standard standby backup batteries.\u003csup class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cb\u003eLoop Cabling:\u003c\/b\u003e Connect the 2-core addressable loop cable to field devices, ensuring proper device address settings and polarity compliance.\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cb\u003eNotification Circuits:\u003c\/b\u003e Wire conventional alarm sounders or strobe beacons to the 24V DC sounder output terminals.\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cb\u003eSystem Commissioning:\u003c\/b\u003e Power up the panel, run auto-learning device enrollment, verify all 100 address points, and log initial testing baseline settings.\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cdiv\u003e\u003cb\u003eHow many total addressable devices can be connected to the VSAIL VI-6811\/100 control panel?\u003c\/b\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv\u003e\n\u003cspan class=\"citation-22\"\u003eThis model supports a maximum capacity of \u003c\/span\u003e\u003cb\u003e\u003cspan class=\"citation-22\"\u003e100 intelligent addressable devices\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-22 citation-end-22\"\u003e (such as detectors, manual call points, and control modules) on its single detection loop.\u003csup class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv\u003e\u003cb\u003eWhere can I buy genuine VSAIL addressable fire alarm panels in Metro Manila?\u003c\/b\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv\u003eOriginal VSAIL fire protection panels and addressable detectors are available at \u003cb\u003eElectx Electrical Supply\u003c\/b\u003e, located in Quiapo, Manila, and online\u003ca rel=\"noopener\" href=\"https:\/\/www.google.com\/search?q=https%3A%2F%2Fwww.electxelectricalsupply.com\" class=\"ng-star-inserted\" target=\"_blank\"\u003eelectx electrical supply\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv\u003e\u003cb\u003eDoes the VSAIL VI-6811\/100 store past alarm and trouble events?\u003c\/b\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv\u003e\n\u003cspan class=\"citation-21\"\u003eYes, the panel features non-volatile memory capable of logging up to \u003c\/span\u003e\u003cb\u003e\u003cspan class=\"citation-21\"\u003e1,000 historical events\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-21 citation-end-21\"\u003e for post-incident reporting and routine maintenance audits.\u003csup class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"VSAIL","offers":[{"title":"Default Title","offer_id":43180498354251,"sku":"VI-6811\/100","price":52050.0,"currency_code":"PHP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0616\/9732\/7179\/files\/VSAIL_Addressable_Fire_Control_Panel_Single_Loop_100_Devices_VI-6811_100_Electx_Electrical_Supply.jpg?v=1789030720","url":"https:\/\/electxelectrical.myshopify.com\/products\/vsail-addressable-fire-control-panel-single-loop-100-devices-vi-6811-100","provider":"Electx Electrical Supply","version":"1.0","type":"link"}