{"product_id":"nema-1-metal-panel-box-enclosure-for-industrial-circuit-breaker-hdm3-6","title":"Nema 1 Metal Panel Box Enclosure For Industrial Circuit Breaker HDM3-630\/3300","description":"A \u003cb data-index-in-node=\"2\" data-path-to-node=\"0\"\u003eNEMA 1 Metal Panel Box Enclosure\u003c\/b\u003e designed for the \u003cb data-index-in-node=\"52\" data-path-to-node=\"0\"\u003eHimel HDM3-630 (630A Frame, 3-Pole)\u003c\/b\u003e Molded Case Circuit Breaker (MCCB) provides standard indoor protection against dust, dirt, and accidental contact with live electrical components.\n\u003ch3 data-path-to-node=\"2\"\u003eKey Specifications \u0026amp; Compatibility\u003c\/h3\u003e\n\n\u003cul data-path-to-node=\"3\"\u003e\n\t\u003cli\u003e\n\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,0,0\"\u003eBreaker Compatibility\u003c\/b\u003e: Himel HDM3-630 \/ HDM3-630F \/ HDM3-630A 3-Pole MCCB\n\n\t\u003cul data-path-to-node=\"3,0,1\"\u003e\n\t\t\u003cli\u003e\n\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,0,1,0,0\"\u003eBreaker Dimensions\u003c\/b\u003e: 257 mm (H) × 150 mm (W) × 107.5 mm (D)\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,1,0\"\u003eProtection Rating\u003c\/b\u003e: \u003cb data-index-in-node=\"19\" data-path-to-node=\"3,1,0\"\u003eNEMA 1 \/ IP20 or IP30\u003c\/b\u003e\n\t\u003cul data-path-to-node=\"3,1,1\"\u003e\n\t\t\u003cli\u003eIntended for indoor use in dry, non-corrosive, non-hazardous environments.\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,2,0\"\u003eMaterial \u0026amp; Construction\u003c\/b\u003e:\n\t\u003cul data-path-to-node=\"3,2,1\"\u003e\n\t\t\u003cli\u003eCold-Rolled Steel (Gauge #16 \/ 1.5mm thickness).\u003c\/li\u003e\n\t\t\u003cli\u003eElectro-galvanized or electrostatically applied \u003cb data-index-in-node=\"48\" data-path-to-node=\"3,2,1,1,0\"\u003eGray Powder-Coated Finish\u003c\/b\u003e (RAL 7035 \/ ANSI 61 Gray).\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,3,0\"\u003eRecommended Dimensions\u003c\/b\u003e: \u003cb data-index-in-node=\"24\" data-path-to-node=\"3,3,0\"\u003e28\" H × 14\" W × 8\" D\u003c\/b\u003e (approx. 710 mm × 355 mm × 200 mm)\n\t\u003cul data-path-to-node=\"3,3,1\"\u003e\n\t\t\u003cli\u003eProvides sufficient wire-bending space and clearance for heavy conductors up to 630A (e.g., dual 240 mm² or 300 mm² per phase).\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 data-path-to-node=\"5\"\u003eFeatures \u0026amp; Design Elements\u003c\/h3\u003e\n\n\u003col data-path-to-node=\"6\" start=\"1\"\u003e\n\t\u003cli\u003e\n\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,0,0\"\u003eMounting Plate\u003c\/b\u003e: Removable zinc-plated or painted interior backplate pre-drilled to match the mounting footprint of the HDM3-630 frame.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,1,0\"\u003eDoor \u0026amp; Cover Options\u003c\/b\u003e:\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003cul data-path-to-node=\"7\"\u003e\n\t\u003cli\u003eHinged front door with a key lock or quarter-turn latch system.\u003c\/li\u003e\n\t\u003cli\u003eDirect-operating cutout for the breaker toggle handle, or an optional door-interlocked external rotary operating handle mechanism.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003col data-path-to-node=\"8\" start=\"3\"\u003e\n\t\u003cli\u003e\n\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,0,0\"\u003eCable Entry\u003c\/b\u003e: Concentric knockouts located on top, bottom, and side panels for standard conduit fittings.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,1,0\"\u003eSafety \u0026amp; Grounding\u003c\/b\u003e: Integrated copper grounding terminal\/busbar inside the enclosure.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3 data-path-to-node=\"10\"\u003eInstallation \u0026amp; Wiring Checklist\u003c\/h3\u003e\n\n\u003cul data-path-to-node=\"11\"\u003e\n\t\u003cli\u003e\n\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,0,0\"\u003ePhase Barriers\u003c\/b\u003e: Always install the extended terminal phase insulation barriers provided with the HDM3-630 MCCB inside the panel box.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,1,0\"\u003eWire Bending Space\u003c\/b\u003e: Ensure the enclosure height allows compliance with local electrical code requirements for bending radius when terminating heavy gauge cables or busbars.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,2,0\"\u003eEnvironment\u003c\/b\u003e: Verify the installation area remains dry and indoor. For outdoor, rain-exposed, or high-humidity areas, use a NEMA 3R or NEMA 4X enclosure instead.\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Local","offers":[{"title":"Default Title","offer_id":67224455872587,"sku":"NEMA1HDM3630AF3P","price":6850.0,"currency_code":"PHP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0616\/9732\/7179\/files\/Nema_1_Metal_Panel_Box_Enclosure_For_Industrial_Circuit_Breaker_HDM3-630_3300_Electx_Electrical_Supply.jpg?v=1791867427","url":"https:\/\/electxelectrical.myshopify.com\/products\/nema-1-metal-panel-box-enclosure-for-industrial-circuit-breaker-hdm3-6","provider":"Electx Electrical Supply","version":"1.0","type":"link"}