{"product_id":"ls-25a-3pole-miniature-circuit-breaker-10-kaic-230v-la63h3p25a","title":"LS 25A 3Pole Miniature Circuit Breaker 10 KAIC 230V LA63H3P25A","description":"\u003cp\u003eLS 25A 3-pole miniature circuit breaker designed for reliable overcurrent protection in residential and light commercial applications. Features 10 KAIC breaking capacity at 230V, ensuring safe disconnection during fault conditions. The LA63H3P25A model delivers compact installation with standard DIN rail mounting. Ideal for protecting branch circuits and distribution boards where space efficiency and dependable performance are essential.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp id=\"p-rc_66cfd272ef460f70-38\"\u003e\u003cspan class=\"citation-61\"\u003eThe \u003c\/span\u003e\u003cb\u003e\u003cspan class=\"citation-61\"\u003eLS 25A 3-Pole Miniature Circuit Breaker (10 KAIC, 230V\/400V, LA63H3P25A)\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-61\"\u003e is a high-performance modular circuit protection device from \u003c\/span\u003e\u003cb\u003e\u003cspan class=\"citation-61\"\u003eLS Electric\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-61 citation-end-61\"\u003e, built to protect three-phase electrical circuits against overloads and short circuits.\u003csup class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications \u0026amp; Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eManufacturer \/ Brand:\u003c\/b\u003e LS Electric\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eModel \/ Part Number:\u003c\/b\u003e LA63H3P25A (LS LA63H \/ BK63H high-capacity series)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_66cfd272ef460f70-39\"\u003e\u003cb\u003eRated Current (\u003cspan class=\"math-inline\"\u003e$I_n$\u003c\/span\u003e):\u003c\/b\u003e \u003cspan class=\"citation-60 citation-end-60\"\u003e25 Amps\u003csup class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_66cfd272ef460f70-40\"\u003e\u003cb\u003eNumber of Poles:\u003c\/b\u003e \u003cspan class=\"citation-59 citation-end-59\"\u003e3-Pole (3P) – designed for three-phase systems\u003csup class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_66cfd272ef460f70-41\"\u003e\u003cb\u003eBreaking Capacity (KAIC \/ \u003cspan class=\"math-inline\"\u003e$I_cu$\u003c\/span\u003e):\u003c\/b\u003e \u003cspan class=\"citation-58 citation-end-58\"\u003e10 kA (10,000 Amps interrupting capacity), ensuring safe clearance of moderate to heavy short-circuit faults\u003csup class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_66cfd272ef460f70-42\"\u003e\u003cb\u003eRated Voltage:\u003c\/b\u003e \u003cspan class=\"citation-57 citation-end-57\"\u003e230V \/ 400V AC\u003csup class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_66cfd272ef460f70-43\"\u003e\u003cb\u003eMounting Type:\u003c\/b\u003e \u003cspan class=\"citation-56 citation-end-56\"\u003eDIN Rail mounting for standardized installation in distribution panels and enclosures\u003csup class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKey Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_66cfd272ef460f70-44\"\u003e\u003cb\u003eThree-Phase Equipment Protection:\u003c\/b\u003e \u003cspan class=\"citation-55 citation-end-55\"\u003eIdeal for safeguarding small three-phase motors, pumps, commercial machinery, and distribution sub-circuits.\u003csup class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCommercial \u0026amp; Industrial Panels:\u003c\/b\u003e Fits neatly into standard distribution boards and control panels where a 10 kA fault interruption rating is required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"LS","offers":[{"title":"Default Title","offer_id":42987225448523,"sku":"LA63H3P25A","price":1150.0,"currency_code":"PHP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0616\/9732\/7179\/files\/LS_25A_3Pole_Miniature_Circuit_Breaker_10_KAIC_230V_LA63H3P25A_Electx_1.jpg?v=1785897887","url":"https:\/\/electxelectrical.myshopify.com\/products\/ls-25a-3pole-miniature-circuit-breaker-10-kaic-230v-la63h3p25a","provider":"Electx Electrical Supply","version":"1.0","type":"link"}