{"product_id":"himel-6a-3p-n-30ma-6-kaic-220v-residual-current-operated-circuit-breaker-rcbo-with-overload-protection-hdb3le3c-copy","title":"Himel 63A 4P+N 30mA 6 KAIC 220V Residual Current Operated Circuit Breaker RCBO with Overload Protection HDB3LE4C","description":"\u003cp\u003eHimel 63A 4P+N 30mA RCBO with integrated overload protection delivers reliable electrical safety for three-phase and neutral circuits. Rated at 220V with 6 KAIC breaking capacity, this residual current operated circuit breaker automatically disconnects when it detects earth faults or leakage currents exceeding 30mA, protecting personnel and equipment from electrocution and fire hazards. The HDB3LE4C model combines dual protection—residual current detection and thermal-magnetic overload sensing—in a single compact device, reducing installation complexity and panel space requirements. Ideal for industrial, commercial, and residential applications where simultaneous protection against both ground faults and overcurrent conditions is essential. Features 4-pole plus neutral configuration for comprehensive circuit control, meeting international safety standards for electrical installations. Suitable for main distribution boards, sub-distribution panels, and branch circuits requiring enhanced fault protection.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv class=\"markdown markdown-main-panel tutor-markdown-rendering enable-luminous-fast-follows stronger enable-updated-hr-color\" id=\"model-response-message-contentr_b0de119cbb805c3c\" aria-live=\"polite\" aria-busy=\"false\" dir=\"ltr\"\u003e\n\u003cp data-path-to-node=\"0\"\u003eThe Himel HDB3LE Series RCBO provides comprehensive, heavy-duty circuit defense designed to manage high-capacity electrical demands across commercial, industrial, and main distribution setups. Engineered under model configuration HDB3LE4C, this 4-pole device manages a maximum continuous load profile up to 63A. It delivers multi-layered protection by integrating miniature circuit breaker (MCB) thermal-magnetic overload safety alongside a highly responsive 30mA electronic residual current device (RCD) assembly, safely interrupting ground faults and high short-circuit values up to 6 kA (6KAIC) at 220V\/400V.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"1\"\u003eKey Technical Specifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"2\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,0,0\"\u003e\u003cb data-path-to-node=\"2,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e Himel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,1,0\"\u003e\u003cb data-path-to-node=\"2,1,0\" data-index-in-node=\"0\"\u003eModel Range:\u003c\/b\u003e HDB3LE Series\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,2,0\"\u003e\u003cb data-path-to-node=\"2,2,0\" data-index-in-node=\"0\"\u003eModel Reference:\u003c\/b\u003e HDB3LE4C (with 63A rating execution)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,3,0\"\u003e\u003cb data-path-to-node=\"2,3,0\" data-index-in-node=\"0\"\u003eNumber of Poles:\u003c\/b\u003e 4-Pole (4P)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,4,0\"\u003e\u003cb data-path-to-node=\"2,4,0\" data-index-in-node=\"0\"\u003eRated Current (In):\u003c\/b\u003e 63A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,5,0\"\u003e\u003cb data-path-to-node=\"2,5,0\" data-index-in-node=\"0\"\u003eResidual Operating Current (IΔn):\u003c\/b\u003e 30mA (High Sensitivity)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,6,0\"\u003e\u003cb data-path-to-node=\"2,6,0\" data-index-in-node=\"0\"\u003eBreaking Capacity:\u003c\/b\u003e 6 kA (6KAIC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,7,0\"\u003e\u003cb data-path-to-node=\"2,7,0\" data-index-in-node=\"0\"\u003eRated Operational Voltage (Ue):\u003c\/b\u003e 220V \/ 400V AC (50\/60Hz)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,8,0\"\u003e\u003cb data-path-to-node=\"2,8,0\" data-index-in-node=\"0\"\u003eProtection Technology:\u003c\/b\u003e Thermal-Magnetic (Overload \u0026amp; Short Circuit) + Electronic Earth Leakage Protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,9,0\"\u003e\u003cb data-path-to-node=\"2,9,0\" data-index-in-node=\"0\"\u003eStandard Compliance:\u003c\/b\u003e Conforms to IEC\/EN 61009-1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,10,0\"\u003e\u003cb data-path-to-node=\"2,10,0\" data-index-in-node=\"0\"\u003eMounting Type:\u003c\/b\u003e 35mm DIN Rail Mount\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"3\"\u003eFeature Summary\u003c\/h3\u003e\n\u003cul data-path-to-node=\"4\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,0,0\"\u003e\u003cb data-path-to-node=\"4,0,0\" data-index-in-node=\"0\"\u003eMaximum Current Carrying Safety:\u003c\/b\u003e Engineered specifically to manage heavy-duty 3-phase machinery and primary lighting or power branches running up to 63A without sacrificing life-safety leakage sensitivities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,1,0\"\u003e\u003cb data-path-to-node=\"4,1,0\" data-index-in-node=\"0\"\u003eFull 4-Pole Circuit Isolation:\u003c\/b\u003e Operates across four fully protected power lines simultaneously, maintaining an instantaneous disconnect across all connected phases the millisecond an unsafe 30mA imbalance to earth occurs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,2,0\"\u003e\u003cb data-path-to-node=\"4,2,0\" data-index-in-node=\"0\"\u003eHeavy Industrial Reliability:\u003c\/b\u003e Built to operate efficiently inside tough environments, utilizing precise front-facing mechanical handles and distinct indicator blocks to swiftly flag whether a circuit interruption was sparked by overcurrent loads or deep earth faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"5\"\u003eThis authentic Himel high-amperage residual current operated circuit breaker with integrated overload protection is fully stocked and available at Electx Electrical Supply to safeguard your low-voltage power networks, electrical panels, and facility distribution configurations.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Himel","offers":[{"title":"Default Title","offer_id":42724497817675,"sku":"HDB3LE4C63","price":3250.0,"currency_code":"PHP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0616\/9732\/7179\/files\/Himel_63A_4P_N_30mA_6_KAIC_220V_Residual_Current_Operated_Circuit_Breaker_RCBO_with_Overload_Protection_HDB3LE4C_Electx_ELectrical_Supply.jpg?v=1782543394","url":"https:\/\/electxelectrical.myshopify.com\/products\/himel-6a-3p-n-30ma-6-kaic-220v-residual-current-operated-circuit-breaker-rcbo-with-overload-protection-hdb3le3c-copy","provider":"Electx Electrical Supply","version":"1.0","type":"link"}