{"product_id":"himel-6a-3p-n-30ma-6-kaic-220v-residual-current-operated-circuit-breaker-rcbo-with-overload-protection-hdb3le3c-copy-3","title":"Himel 32A 3P+N 30mA 6 KAIC 220V Residual Current Operated Circuit Breaker RCBO with Overload Protection HDB3LE3C32","description":"\u003cp data-path-to-node=\"0\"\u003eThe Himel HDB3LE3C32 is a high-capacity Residual Current Operated Circuit Breaker with Overload Protection (RCBO), designed for complete 3P+N safeguarding in three-phase electrical distribution systems. It merges high-sensitivity ground leakage detection with thermal-magnetic overload and short-circuit protection within a single modular unit.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"1\"\u003eCore Features \u0026amp; Protection\u003c\/h3\u003e\n\u003cul data-path-to-node=\"2\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,0,0\"\u003e\u003cb data-path-to-node=\"2,0,0\" data-index-in-node=\"0\"\u003eDual-Function Circuit Protection:\u003c\/b\u003e Combines residual current protection (RCD) and overcurrent defense (MCB) into one device, saving panel enclosure space while ensuring total circuit isolation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,1,0\"\u003e\u003cb data-path-to-node=\"2,1,0\" data-index-in-node=\"0\"\u003e30mA Ground Fault Safeguard:\u003c\/b\u003e Engineered with a 30mA residual tripping sensitivity (\u003cspan class=\"math-inline\" data-math=\"\\Delta n = 30\\text{ mA}\" data-index-in-node=\"83\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003eΔ\u003c\/span\u003e\u003cspan class=\"mord mathnormal\"\u003en\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003cspan class=\"mrel\"\u003e=\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e30\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e mA\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e) to immediately disconnect power upon sensing stray earth leakage currents, protecting personnel against severe electric shock.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,2,0\"\u003e\u003cb data-path-to-node=\"2,2,0\" data-index-in-node=\"0\"\u003e3P+N Four-Pole Switching:\u003c\/b\u003e Disconnects all three phase conductors along with a dedicated neutral pole to provide complete galvanic isolation across balanced or unbalanced three-phase power networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,3,0\"\u003e\u003cb data-path-to-node=\"2,3,0\" data-index-in-node=\"0\"\u003eType C Tripping Profile:\u003c\/b\u003e Utilizes a C-curve trip mechanism to accommodate moderate inductive surge currents, preventing nuisance tripping during the startup of commercial appliances, pumps, and machinery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"3\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"4\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,0,0\"\u003e\u003cb data-path-to-node=\"4,0,0\" data-index-in-node=\"0\"\u003eBrand \u0026amp; Series:\u003c\/b\u003e Himel (HDB3LE Series)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,1,0\"\u003e\u003cb data-path-to-node=\"4,1,0\" data-index-in-node=\"0\"\u003eModel \/ Part Number:\u003c\/b\u003e HDB3LE3C32\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,2,0\"\u003e\u003cb data-path-to-node=\"4,2,0\" data-index-in-node=\"0\"\u003eRated Current (\u003cspan class=\"math-inline\" data-math=\"I_n\" data-index-in-node=\"15\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e\u003cspan class=\"mord mathnormal\"\u003eI\u003c\/span\u003e\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t vlist-t2\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mathnormal mtight\"\u003en\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-s\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e):\u003c\/b\u003e 32 Amperes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,3,0\"\u003e\u003cb data-path-to-node=\"4,3,0\" data-index-in-node=\"0\"\u003eNumber of Poles:\u003c\/b\u003e 3P + Neutral (3P+N)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,4,0\"\u003e\u003cb data-path-to-node=\"4,4,0\" data-index-in-node=\"0\"\u003eResidual Current Sensitivity (\u003cspan class=\"math-inline\" data-math=\"\\Delta n\" data-index-in-node=\"30\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003eΔ\u003c\/span\u003e\u003cspan class=\"mord mathnormal\"\u003en\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e):\u003c\/b\u003e 30mA (Instantaneous)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,5,0\"\u003e\u003cb data-path-to-node=\"4,5,0\" data-index-in-node=\"0\"\u003eRated Breaking Capacity (\u003cspan class=\"math-inline\" data-math=\"I_{cn}\" data-index-in-node=\"25\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e\u003cspan class=\"mord mathnormal\"\u003eI\u003c\/span\u003e\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t vlist-t2\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mtight\"\u003e\u003cspan class=\"mord mathnormal mtight\"\u003ec\u003c\/span\u003e\u003cspan class=\"mord mathnormal mtight\"\u003en\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-s\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e):\u003c\/b\u003e 6 kA (6000A)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,6,0\"\u003e\u003cb data-path-to-node=\"4,6,0\" data-index-in-node=\"0\"\u003eOperating Voltage:\u003c\/b\u003e 220V \/ 400V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,7,0\"\u003e\u003cb data-path-to-node=\"4,7,0\" data-index-in-node=\"0\"\u003eMounting Standard:\u003c\/b\u003e 35mm DIN Rail\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,8,0\"\u003e\u003cb data-path-to-node=\"4,8,0\" data-index-in-node=\"0\"\u003eStandards Compliance:\u003c\/b\u003e IEC\/EN 61009-1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"5\"\u003ePrimary Applications\u003c\/h3\u003e\n\u003cp data-path-to-node=\"6\"\u003eWell-suited for higher-amperage sub-panels, workshop machinery, HVAC plant units, and commercial three-phase distribution circuits requiring reliable 32A load capacity alongside stringent earth leakage and overcurrent safety.\u003c\/p\u003e\n\u003cp data-path-to-node=\"8\"\u003eAvailable at Electx Electrical Supply.\u003c\/p\u003e","brand":"Himel","offers":[{"title":"Default Title","offer_id":42940327854155,"sku":"HDB3LE3C32","price":2200.0,"currency_code":"PHP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0616\/9732\/7179\/files\/Himel_32A_3P_N_30mA_6_KAIC_220V_Residual_Current_Operated_Circuit_Breaker_RCBO_with_Overload_Protection_HDB3LE3C32-A.jpg?v=1784880470","url":"https:\/\/electxelectrical.myshopify.com\/products\/himel-6a-3p-n-30ma-6-kaic-220v-residual-current-operated-circuit-breaker-rcbo-with-overload-protection-hdb3le3c-copy-3","provider":"Electx Electrical Supply","version":"1.0","type":"link"}