{"product_id":"himel-6a-3p-n-30ma-6-kaic-220v-residual-current-operated-circuit-breaker-rcbo-with-overload-protection-hdb3le3c-copy-2","title":"Himel 16A 3P+N 30mA 6 KAIC 220V Residual Current Operated Circuit Breaker RCBO with Overload Protection HDB3LE3C16","description":"\u003cp\u003e\u003cspan\u003eThe Himel HDB3LE3C16 is an all-in-one Residual Current Operated Circuit Breaker with Overload Protection (RCBO), designed to deliver comprehensive 3P+N protection for 3-phase low-voltage distribution systems. It combines residual current leakage detection with traditional MCB thermal-magnetic protection against overloads and short circuits in a single modular enclosure.\u003cbr\u003e\u003cbr\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"2\"\u003eCore Features \u0026amp; Protection\u003c\/h3\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eComplete Circuit Safety:\u003c\/b\u003e Merges ground leakage protection (RCD) with overcurrent and short-circuit protection (MCB), eliminating the need for a separate RCCB and MCB combination.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eHigh Sensitivity Personnel Protection:\u003c\/b\u003e Features a 30mA residual tripping sensitivity (\u003cspan class=\"math-inline\" data-math=\"\\Delta n = 30\\text{ mA}\" data-index-in-node=\"86\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003eΔ\u003c\/span\u003e\u003cspan class=\"mord mathnormal\"\u003en\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003cspan class=\"mrel\"\u003e=\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e30\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e mA\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e) to immediately disconnect power upon detecting earth leakage currents, guarding against fatal electric shocks and equipment insulation failures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003e3P+N Configuration:\u003c\/b\u003e Controls three phase lines alongside a dedicated neutral pole, making it suitable for balanced or unbalanced three-phase 220V\/400V circuit applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eC-Curve Tripping Characteristic:\u003c\/b\u003e Optimized for general residential and commercial electrical loads with moderate inductive inrush currents, such as HVAC units, small motors, and office power circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"4\"\u003eKey Specifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eBrand \u0026amp; Series:\u003c\/b\u003e Himel (HDB3LE Series)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eModel Part Number:\u003c\/b\u003e HDB3LE3C16\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eRated Current (\u003cspan class=\"math-inline\" data-math=\"I_n\" data-index-in-node=\"15\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e\u003cspan class=\"mord mathnormal\"\u003eI\u003c\/span\u003e\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t vlist-t2\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mathnormal mtight\"\u003en\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-s\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e):\u003c\/b\u003e 16 Amperes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eNumber of Poles:\u003c\/b\u003e 3P + Neutral (3P+N)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\"\u003eSensitivity Rating (\u003cspan class=\"math-inline\" data-math=\"\\Delta n\" data-index-in-node=\"20\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003eΔ\u003c\/span\u003e\u003cspan class=\"mord mathnormal\"\u003en\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e):\u003c\/b\u003e 30mA (Instantaneous)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\"\u003eBreaking Capacity (\u003cspan class=\"math-inline\" data-math=\"I_{cn}\" data-index-in-node=\"19\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e\u003cspan class=\"mord mathnormal\"\u003eI\u003c\/span\u003e\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t vlist-t2\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mtight\"\u003e\u003cspan class=\"mord mathnormal mtight\"\u003ec\u003c\/span\u003e\u003cspan class=\"mord mathnormal mtight\"\u003en\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-s\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e):\u003c\/b\u003e 6 kA (6000A at 220V\/400V AC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\"\u003eMounting Type:\u003c\/b\u003e Standard 35mm DIN rail mount for easy installation in distribution boards and panelboards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\"\u003eCompliance \u0026amp; Certification:\u003c\/b\u003e IEC\/EN 61009-1 compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\"\u003eTypical Applications\u003c\/h3\u003e\n\u003cp data-path-to-node=\"7\"\u003eIdeal for protecting commercial buildings, workshops, and light industrial sub-panels requiring three-phase power where individual circuit leakage current detection and overcurrent safeguarding are mandatory.\u003c\/p\u003e\n\u003cp data-path-to-node=\"9\"\u003eAvailable at Electx Electrical Supply.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Himel","offers":[{"title":"Default Title","offer_id":42940316909643,"sku":"HDB3LE3C16","price":2200.0,"currency_code":"PHP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0616\/9732\/7179\/files\/Himel16A3P_N30mA6KAIC220VResidualCurrentOperatedCircuitBreakerRCBOwithOverloadProtectionHDB3LE3C.jpg?v=1784867591","url":"https:\/\/electxelectrical.myshopify.com\/products\/himel-6a-3p-n-30ma-6-kaic-220v-residual-current-operated-circuit-breaker-rcbo-with-overload-protection-hdb3le3c-copy-2","provider":"Electx Electrical Supply","version":"1.0","type":"link"}