{"product_id":"himel-20a-3p-25kaic-400v-molded-case-circuit-breaker-3-phase-35kaic-22","title":"Himel 20A 3P 25KAIC 400V Molded Case Circuit Breaker 3 Phase 35KAIC 220V HDM3100S2033XX","description":"\u003cp\u003eHimel molded case circuit breaker designed for three-phase electrical systems. Rated 20A with 25KAIC breaking capacity at 400V and 35KAIC at 220V. Model HDM3100S2033XX provides reliable overcurrent protection for industrial and commercial applications. Compact design allows easy installation in distribution boards and control panels. Suitable for motor circuits, feeder protection, and general load switching. Meets international safety standards for dependable performance.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv class=\"markdown markdown-main-panel md-content enable-luminous-fast-follows enable-updated-hr-color stronger tutor-markdown-rendering\" id=\"model-response-message-contentr_8ffd7d49b0bd3f78\" aria-busy=\"false\" aria-live=\"polite\" dir=\"ltr\"\u003e\n\u003cdiv\u003eThe \u003cb data-path-to-node=\"0\" data-index-in-node=\"4\"\u003eHimel HDM3100S2033XX\u003c\/b\u003e (catalog code \u003ccode data-path-to-node=\"0\" data-index-in-node=\"39\"\u003eHDM3-100S\/3300 20A\u003c\/code\u003e) is a 3-pole Molded Case Circuit Breaker (MCCB) from the Himel HDM3 series, engineered for low-voltage 3-phase power distribution and industrial line protection.\u003c\/div\u003e\n\u003cbr\u003e\n\u003ch3 data-path-to-node=\"1\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"2\"\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cb data-path-to-node=\"2,0,0\" data-index-in-node=\"0\"\u003eBrand \u0026amp; Series:\u003c\/b\u003e Himel HDM3 Series\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cb data-path-to-node=\"2,1,0\" data-index-in-node=\"0\"\u003eFull Part Number:\u003c\/b\u003e HDM3100S2033XX\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cb data-path-to-node=\"2,2,0\" data-index-in-node=\"0\"\u003eFrame Size:\u003c\/b\u003e 100AF\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cb data-path-to-node=\"2,3,0\" data-index-in-node=\"0\"\u003eNumber of Poles:\u003c\/b\u003e 3 Pole (3P \/ 3-Phase)\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cb data-path-to-node=\"2,4,0\" data-index-in-node=\"0\"\u003eRated Current (\u003cspan class=\"math-inline\" data-math=\"I_n\" data-index-in-node=\"15\"\u003e$I_n$\u003c\/span\u003e):\u003c\/b\u003e 20A\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cb data-path-to-node=\"2,5,0\" data-index-in-node=\"0\"\u003eBreaking Capacity Tier:\u003c\/b\u003e \u003cb data-path-to-node=\"2,5,0\" data-index-in-node=\"24\"\u003eS\u003c\/b\u003e (Standard Performance Tier)\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cb data-path-to-node=\"2,6,0\" data-index-in-node=\"0\"\u003eRated Operational Voltage (\u003cspan class=\"math-inline\" data-math=\"U_e\" data-index-in-node=\"27\"\u003e$U_e$\u003c\/span\u003e):\u003c\/b\u003e 380V \/ 400V \/ 415V \/ 690V AC (50\/60 Hz)\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cb data-path-to-node=\"2,7,0\" data-index-in-node=\"0\"\u003eRated Insulation Voltage (\u003cspan class=\"math-inline\" data-math=\"U_i\" data-index-in-node=\"26\"\u003e$U_i$\u003c\/span\u003e):\u003c\/b\u003e 800V\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cb data-path-to-node=\"2,8,0\" data-index-in-node=\"0\"\u003eRated Impulse Withstand Voltage (\u003cspan class=\"math-inline\" data-math=\"U_{imp}\" data-index-in-node=\"33\"\u003e$U_{imp}$\u003c\/span\u003e):\u003c\/b\u003e 8 kV\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"4\"\u003eBreaking Capacity Ratings (\u003cspan class=\"math-inline\" data-math=\"I_{cu}\" data-index-in-node=\"27\"\u003e$I_{cu}$\u003c\/span\u003e \/ \u003cspan class=\"math-inline\" data-math=\"I_{cs}\" data-index-in-node=\"36\"\u003e$I_{cs}$\u003c\/span\u003e)\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eAt 220V \/ 240V AC:\u003c\/b\u003e \u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"19\"\u003e35 kAIC\u003c\/b\u003e (\u003cspan class=\"math-inline\" data-math=\"I_{cu}\" data-index-in-node=\"28\"\u003e$I_{cu}$\u003c\/span\u003e) \/ 25 kA (\u003cspan class=\"math-inline\" data-math=\"I_{cs}\" data-index-in-node=\"45\"\u003e$I_{cs}$\u003c\/span\u003e)\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eAt 380V \/ 400V AC:\u003c\/b\u003e \u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"19\"\u003e25 kAIC\u003c\/b\u003e (\u003cspan class=\"math-inline\" data-math=\"I_{cu}\" data-index-in-node=\"28\"\u003e$I_{cu}$\u003c\/span\u003e) \/ 18 kA (\u003cspan class=\"math-inline\" data-math=\"I_{cs}\" data-index-in-node=\"45\"\u003e$I_{cs}$\u003c\/span\u003e)\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eAt 415V AC:\u003c\/b\u003e \u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"12\"\u003e22 kAIC\u003c\/b\u003e (\u003cspan class=\"math-inline\" data-math=\"I_{cu}\" data-index-in-node=\"21\"\u003e$I_{cu}$\u003c\/span\u003e) \/ 15 kA (\u003cspan class=\"math-inline\" data-math=\"I_{cs}\" data-index-in-node=\"38\"\u003e$I_{cs}$\u003c\/span\u003e)\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"7\"\u003eKey Applications \u0026amp; Characteristics\u003c\/h3\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cdiv\u003eDesigned for low-current 3-phase main distribution, branch circuit protection, small motors, and HVAC control circuits.\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003eFeatures a fixed thermal-magnetic trip mechanism calibrated for standard \u003cspan class=\"math-inline\" data-math=\"40^\\circ\\text{C}\" data-index-in-node=\"73\"\u003e$40^\\circ\\text{C}$\u003c\/span\u003e ambient operation.\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003eFully compliant with IEC \/ EN 60947-2 industrial safety standards.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Himel","offers":[{"title":"Default Title","offer_id":67275164483659,"sku":"HDM3100S2033XX","price":4350.0,"currency_code":"PHP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0616\/9732\/7179\/files\/Himel_20A_3P_25KAIC_400V_Molded_Case_Circuit_Breaker_3_Phase_35KAIC_220V_HDM3100S2033XX_Electx_Electrical_SUpply.jpg?v=1792382309","url":"https:\/\/electxelectrical.myshopify.com\/products\/himel-20a-3p-25kaic-400v-molded-case-circuit-breaker-3-phase-35kaic-22","provider":"Electx Electrical Supply","version":"1.0","type":"link"}