{"product_id":"himel-10a-4p-n-30ma-6-kaic-220v-residual-current-operated-circuit-breaker-rcbo-with-overload-protection-hdb3le4c10","title":"Himel 10A 4P+N 30mA 6 KAIC 220V Residual Current Operated Circuit Breaker RCBO with Overload Protection HDB3LE4C10","description":"\u003cp data-path-to-node=\"0\"\u003eThe Himel HDB3LE4C10 is a compact 4-pole Residual Current Operated Circuit Breaker with Overload Protection (RCBO), engineered to deliver precise ground leakage, overload, and short-circuit protection for low-amperage three-phase electrical circuits.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"1\"\u003eCore Features \u0026amp; Protection\u003c\/h3\u003e\n\u003cul data-path-to-node=\"2\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,0,0\"\u003e\u003cb data-path-to-node=\"2,0,0\" data-index-in-node=\"0\"\u003eIntegrated Circuit Defense:\u003c\/b\u003e Unifies residual current protection (RCD) and thermal-magnetic overcurrent protection (MCB) into a single compact DIN-rail device, eliminating the need for separate modules and saving panelboard space.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,1,0\"\u003e\u003cb data-path-to-node=\"2,1,0\" data-index-in-node=\"0\"\u003e30mA Shock \u0026amp; Fault Protection:\u003c\/b\u003e Features a high-sensitivity 30mA earth-leakage tripping threshold (\u003cspan class=\"math-inline\" data-math=\"\\Delta n = 30\\text{ mA}\" data-index-in-node=\"98\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003eΔ\u003c\/span\u003e\u003cspan class=\"mord mathnormal\"\u003en\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003cspan class=\"mrel\"\u003e=\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e30\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e mA\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e) to immediately cut off power upon detecting stray leakage currents, safeguarding personnel from electric shock.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,2,0\"\u003e\u003cb data-path-to-node=\"2,2,0\" data-index-in-node=\"0\"\u003eFull 4-Pole (4P) Isolation:\u003c\/b\u003e Provides thermal-magnetic overcurrent monitoring and complete circuit isolation across all four conductors (L1, L2, L3, and Neutral) for balanced or unbalanced 3-phase, 4-wire systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,3,0\"\u003e\u003cb data-path-to-node=\"2,3,0\" data-index-in-node=\"0\"\u003eType C Tripping Characteristic:\u003c\/b\u003e Calibrated with a C-curve trip mechanism to handle minor inductive inrush currents without nuisance tripping, making it suitable for commercial lighting arrays, small pump units, and control circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"3\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"4\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,0,0\"\u003e\u003cb data-path-to-node=\"4,0,0\" data-index-in-node=\"0\"\u003eBrand \u0026amp; Series:\u003c\/b\u003e Himel (HDB3LE Series)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,1,0\"\u003e\u003cb data-path-to-node=\"4,1,0\" data-index-in-node=\"0\"\u003eModel \/ Part Number:\u003c\/b\u003e HDB3LE4C10\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,2,0\"\u003e\u003cb data-path-to-node=\"4,2,0\" data-index-in-node=\"0\"\u003eRated Current (\u003cspan class=\"math-inline\" data-math=\"I_n\" data-index-in-node=\"15\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e\u003cspan class=\"mord mathnormal\"\u003eI\u003c\/span\u003e\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t vlist-t2\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mathnormal mtight\"\u003en\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-s\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e):\u003c\/b\u003e 10 Amperes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,3,0\"\u003e\u003cb data-path-to-node=\"4,3,0\" data-index-in-node=\"0\"\u003eNumber of Poles:\u003c\/b\u003e 4P (4 Protected Poles)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,4,0\"\u003e\u003cb data-path-to-node=\"4,4,0\" data-index-in-node=\"0\"\u003eResidual Current Sensitivity (\u003cspan class=\"math-inline\" data-math=\"\\Delta n\" data-index-in-node=\"30\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003eΔ\u003c\/span\u003e\u003cspan class=\"mord mathnormal\"\u003en\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e):\u003c\/b\u003e 30mA (Instantaneous)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,5,0\"\u003e\u003cb data-path-to-node=\"4,5,0\" data-index-in-node=\"0\"\u003eRated Breaking Capacity (\u003cspan class=\"math-inline\" data-math=\"I_{cn}\" data-index-in-node=\"25\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e\u003cspan class=\"mord mathnormal\"\u003eI\u003c\/span\u003e\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t vlist-t2\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mtight\"\u003e\u003cspan class=\"mord mathnormal mtight\"\u003ec\u003c\/span\u003e\u003cspan class=\"mord mathnormal mtight\"\u003en\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-s\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e):\u003c\/b\u003e 6 kA (6000A at 220V\/400V AC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,6,0\"\u003e\u003cb data-path-to-node=\"4,6,0\" data-index-in-node=\"0\"\u003eOperating Voltage:\u003c\/b\u003e 220V \/ 400V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,7,0\"\u003e\u003cb data-path-to-node=\"4,7,0\" data-index-in-node=\"0\"\u003eMounting Standard:\u003c\/b\u003e 35mm DIN Rail Mount\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,8,0\"\u003e\u003cb data-path-to-node=\"4,8,0\" data-index-in-node=\"0\"\u003eStandards Compliance:\u003c\/b\u003e IEC\/EN 61009-1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"5\"\u003ePrimary Applications\u003c\/h3\u003e\n\u003cp data-path-to-node=\"6\"\u003eIdeally suited for low-load commercial sub-panels, 3-phase control circuits, dedicated instrument branches, and light industrial equipment requiring precise 10A current limits combined with earth leakage safety.\u003c\/p\u003e\n\u003cp data-path-to-node=\"8\"\u003eAvailable at Electx Electrical Supply.\u003c\/p\u003e","brand":"Himel","offers":[{"title":"Default Title","offer_id":42940570009675,"sku":"HDB3LE4C10","price":3250.0,"currency_code":"PHP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0616\/9732\/7179\/files\/Himel10A4P_N30mA6KAIC220VResidualCurrentOperatedCircuitBreakerRCBOwithOverloadProtectionHDB3LE3C10-5.jpg?v=1784878403","url":"https:\/\/electxelectrical.myshopify.com\/products\/himel-10a-4p-n-30ma-6-kaic-220v-residual-current-operated-circuit-breaker-rcbo-with-overload-protection-hdb3le4c10","provider":"Electx Electrical Supply","version":"1.0","type":"link"}