{"product_id":"dixsen-150-5a-split-core-current-transformer-class-1-burden-1-5-window-size-20-x-30mm-dbp-23-150-5-dbp-23150-5a","title":"Dixsen 150:5A Split Core Current Transformer Class 1 Burden 1.5 Window Size 20 x 30mm DBP-23 150:5 DBP-23150\/5A","description":"\u003ch1\u003eDixsen 150:5A Split Core Current Transformer Class 1, 1.5VA Burden, 20 x 30mm Window – DBP-23, DBP-23150\/5A\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eDixsen 150:5A Split Core Current Transformer (CT)\u003c\/strong\u003e is a practical and reliable current-sensing component designed for electrical metering, monitoring, and measurement applications. Featuring a \u003cstrong\u003e150A primary to 5A secondary ratio\u003c\/strong\u003e, this transformer allows high current flowing through an electrical conductor to be converted into a manageable 5A secondary current for connection to compatible measuring and monitoring equipment.\u003c\/p\u003e\n\u003cp\u003eThis model uses a \u003cstrong\u003esplit-core design\u003c\/strong\u003e, allowing the current transformer to be installed around an existing cable or conductor without requiring the conductor to be disconnected. This makes it especially useful for retrofit installations, electrical panel upgrades, monitoring systems, and maintenance applications where interrupting an existing circuit is not desirable.\u003c\/p\u003e\n\u003cp\u003eThe Dixsen \u003cstrong\u003eDBP-23 150:5A\u003c\/strong\u003e features a \u003cstrong\u003eClass 1 accuracy rating\u003c\/strong\u003e, making it suitable for general-purpose current measurement and metering applications where dependable measurement performance is required. It has a \u003cstrong\u003e1.5VA burden\u003c\/strong\u003e and a \u003cstrong\u003e20 x 30mm window size\u003c\/strong\u003e, providing a compact configuration for installation in electrical panels, distribution boards, control cabinets, and other equipment.\u003c\/p\u003e\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Dixsen\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e DBP-23\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel\/Part Number:\u003c\/strong\u003e DBP-23150\/5A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Transformer Type:\u003c\/strong\u003e Split Core\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrimary Current:\u003c\/strong\u003e 150A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSecondary Current:\u003c\/strong\u003e 5A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRatio:\u003c\/strong\u003e 150:5A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy Class:\u003c\/strong\u003e Class 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBurden:\u003c\/strong\u003e 1.5VA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWindow Size:\u003c\/strong\u003e 20 x 30mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact design\u003c\/strong\u003e suitable for electrical panels and control equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSplit-core construction\u003c\/strong\u003e for easier installation around existing conductors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for \u003cstrong\u003ecurrent measurement, monitoring, and metering applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSplit-Core Design\u003c\/h3\u003e\n\u003cp\u003eOne of the main advantages of the Dixsen DBP-23 is its \u003cstrong\u003esplit-core construction\u003c\/strong\u003e. Unlike conventional solid-core current transformers that generally require the conductor to pass through the CT before termination, a split-core CT can be opened and positioned around an existing cable or bus conductor.\u003c\/p\u003e\n\u003cp\u003eThis installation method can significantly simplify current monitoring projects, particularly when working with existing electrical installations. It is suitable for applications where the electrical system is already operational and circuit disconnection should be minimized.\u003c\/p\u003e\n\u003ch3\u003e150:5A Current Transformer Ratio\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e150:5A ratio\u003c\/strong\u003e means that when the primary current reaches 150A, the corresponding secondary current is 5A. The secondary output can then be connected to compatible meters, monitoring instruments, protection equipment, or other devices designed for a 5A CT secondary.\u003c\/p\u003e\n\u003cp\u003eThe CT provides electrical isolation between the primary power circuit and the secondary measuring circuit while allowing the current flowing through the primary conductor to be monitored by suitable equipment.\u003c\/p\u003e\n\u003ch3\u003e20 x 30mm Window Size\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e20 x 30mm window opening\u003c\/strong\u003e provides space for the applicable cable or conductor to pass through the CT. Before installation, users should verify that the conductor dimensions and installation arrangement are compatible with the CT opening.\u003c\/p\u003e\n\u003cp\u003eIts compact size makes the DBP-23 suitable for installations where available panel space is limited.\u003c\/p\u003e\n\u003ch3\u003eClass 1 Accuracy and 1.5VA Burden\u003c\/h3\u003e\n\u003cp\u003eWith a \u003cstrong\u003eClass 1 accuracy rating\u003c\/strong\u003e and \u003cstrong\u003e1.5VA burden\u003c\/strong\u003e, this Dixsen current transformer is designed for general electrical measurement and monitoring applications. Proper matching between the CT secondary rating, connected meter or instrument, and total secondary circuit burden is recommended to maintain appropriate measurement performance.\u003c\/p\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eThe Dixsen 150:5A Split Core Current Transformer can be used for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical current measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePanel meter applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnergy and power monitoring systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDistribution boards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical control panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial monitoring equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLoad monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilding electrical monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRetrofit electrical installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent measurement systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical maintenance and testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMetering systems requiring a 5A CT secondary\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe \u003cstrong\u003eDixsen DBP-23 150:5A Split Core Current Transformer\u003c\/strong\u003e is a convenient solution for monitoring electrical loads without the need to remove existing conductors. Its \u003cstrong\u003e150:5A ratio, Class 1 accuracy, 1.5VA burden, split-core construction, and 20 x 30mm window\u003c\/strong\u003e make it suitable for a wide range of electrical measurement and monitoring applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAvailable in Electx Electrical Supply.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Dixsen","offers":[{"title":"Default Title","offer_id":41819535245387,"sku":"DBP-23150\/5A","price":4050.0,"currency_code":"PHP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0616\/9732\/7179\/files\/Dixsen1505ASplitCoreCurrentTransformerClass1Burden1.5WindowSize20x30mmElectxElectricalSupply_3.jpg?v=1760085599","url":"https:\/\/electxelectrical.myshopify.com\/products\/dixsen-150-5a-split-core-current-transformer-class-1-burden-1-5-window-size-20-x-30mm-dbp-23-150-5-dbp-23150-5a","provider":"Electx Electrical Supply","version":"1.0","type":"link"}