{"product_id":"boston-pdx-awg-14-2-romex-wire-1-6mm-2c-nm-non-metallic-sheathe-cable","title":"Boston PDX AWG 14\/2 Romex Wire 1.6mm\/2C NM Non Metallic Sheathe Cable 75M\/Roll BPDX1Roll14\/2","description":"\u003cb data-index-in-node=\"0\" data-path-to-node=\"0\"\u003eBoston PDX AWG 14\/2 Romex Wire (1.6mm \/ 2-Conductor) NM Non-Metallic Sheathed Cable - 75 Meters per Roll (Model: BPDX1Roll14\/2)\u003c\/b\u003e\n\u003ch3 data-path-to-node=\"1\"\u003eProduct Overview\u003c\/h3\u003e\nThe \u003cb data-index-in-node=\"4\" data-path-to-node=\"2\"\u003eBoston PDX AWG 14\/2 Non-Metallic (NM) Sheathed Cable\u003c\/b\u003e delivers dependable electrical performance for low-voltage lighting circuits, residential branch wiring, and general power outlets. Engineered with solid copper conductors and a durable PVC outer jacket, this 75-meter roll provides continuous conductivity, high thermal resistance, and optimal protection against moisture, abrasion, and environmental wear.\u003cbr\u003e\nDesigned for indoor electrical installations, this 2-conductor cable (1.6mm per conductor) ensures easy pulling through conduit or wall framing while maintaining strict compliance with residential wiring standards. Whether used for light switch connections, ceiling fan circuits, or standard 15-amp branch lines, Boston PDX cable ensures minimal voltage drop and long-term operating efficiency.\n\u003ch3 data-path-to-node=\"5\"\u003eTechnical Specifications\u003c\/h3\u003e\n\n\u003ctable data-path-to-node=\"6\"\u003e\n\t\u003cthead\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cstrong\u003eSpecification Feature\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cstrong\u003eTechnical Details\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/thead\u003e\n\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,1,0,0\"\u003eBrand\u003c\/b\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003eBoston\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,2,0,0\"\u003eModel Code\u003c\/b\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003eBPDX1Roll14\/2\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,3,0,0\"\u003eCable Type\u003c\/b\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003ePDX \/ NM (Non-Metallic Sheathed Cable)\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,4,0,0\"\u003eWire Gauge\u003c\/b\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003eAWG 14 (1.6mm Conductor Diameter)\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,5,0,0\"\u003eConductor Count\u003c\/b\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e2 Conductors (2C)\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,6,0,0\"\u003eConductor Material\u003c\/b\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003eHigh-Conductivity Annealed Solid Copper\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,7,0,0\"\u003eInsulation Material\u003c\/b\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003eThermoplastic Polyvinyl Chloride (PVC)\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,8,0,0\"\u003eOuter Jacket\u003c\/b\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003eFlame-Retardant Heavy-Duty PVC\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,9,0,0\"\u003eRoll Length\u003c\/b\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e75 Meters (246 Feet)\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,10,0,0\"\u003eVoltage Rating\u003c\/b\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e300V \/ 600V Max\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,11,0,0\"\u003eAmpacity Rating\u003c\/b\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003eUp to 15 Amperes\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,12,0,0\"\u003eTemperature Rating\u003c\/b\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003eDry \/ Indoor Locations up to 75°C \/ 90°C\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,13,0,0\"\u003eColor Code\u003c\/b\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003eBlack, White (Standard 2C Configuration)\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 data-path-to-node=\"8\"\u003eKey Applications \u0026amp; Use Cases\u003c\/h3\u003e\n\n\u003cul data-path-to-node=\"9\"\u003e\n\t\u003cli\u003e\n\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,0,0\"\u003eResidential Lighting Circuits:\u003c\/b\u003e Ideal for connecting LED recessed lights, ceiling fixtures, wall sconces, and light switches.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,1,0\"\u003eGeneral Branch Wiring:\u003c\/b\u003e Suitable for standard indoor 15A wall outlets and power distribution boxes.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,2,0\"\u003eHome Renovation \u0026amp; Rewiring:\u003c\/b\u003e Convenient 75m bulk roll length reduces splice requirements across multi-room wiring layouts.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,3,0\"\u003eConduit and In-Wall Routing:\u003c\/b\u003e Formulated for smooth pulling through PVC conduits, junction boxes, and wooden stud framing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 data-path-to-node=\"11\"\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cb data-index-in-node=\"0\" data-path-to-node=\"12\"\u003eWhat is the wire gauge and conductor size of this Boston PDX cable?\u003c\/b\u003e\u003cbr\u003e\nThis cable uses \u003cb data-index-in-node=\"16\" data-path-to-node=\"13\"\u003e14 AWG solid copper conductors\u003c\/b\u003e, which measure approximately \u003cb data-index-in-node=\"76\" data-path-to-node=\"13\"\u003e1.6mm in diameter per core\u003c\/b\u003e.\u003cbr\u003e\n\u003cb data-index-in-node=\"0\" data-path-to-node=\"14\"\u003eHow long is one full roll of BPDX1Roll14\/2?\u003c\/b\u003e\u003cbr\u003e\nEach full roll contains \u003cb data-index-in-node=\"24\" data-path-to-node=\"15\"\u003e75 meters\u003c\/b\u003e (approximately 246 feet) of continuous non-metallic sheathed cable.\u003cbr\u003e\n\u003cb data-index-in-node=\"0\" data-path-to-node=\"16\"\u003eWhat is the maximum amperage rating for AWG 14\/2 wire?\u003c\/b\u003e\u003cbr\u003e\nAWG 14\/2 electrical wire is rated for circuits up to \u003cb data-index-in-node=\"53\" data-path-to-node=\"17\"\u003e15 Amps\u003c\/b\u003e, making it standard for residential lighting and general receptacle circuits.\u003cbr\u003e\n\u003cb data-index-in-node=\"0\" data-path-to-node=\"18\"\u003eCan this cable be installed outdoors or underground?\u003c\/b\u003e\u003cbr\u003e\nBoston PDX NM cable is designed primarily for indoor dry and damp locations inside conduit or behind walls. For direct burial underground applications, UF-B rated cables are recommended.","brand":"Boston","offers":[{"title":"Default Title","offer_id":43180134498379,"sku":"BPDX1Roll14\/2","price":5558.0,"currency_code":"PHP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0616\/9732\/7179\/files\/Boston_PDX_AWG_14_2_Romex_Wire_1.6mm_2C_NM_Non_Metallic_Sheathe_Cable_75M_Roll_BPDX1Roll14_2_Electx_Electrical_Supply.jpg?v=1789016526","url":"https:\/\/electxelectrical.myshopify.com\/products\/boston-pdx-awg-14-2-romex-wire-1-6mm-2c-nm-non-metallic-sheathe-cable","provider":"Electx Electrical Supply","version":"1.0","type":"link"}